Università degli Studi dell'Insubria Insubria Space
 

InsubriaSPACE - Thesis PhD Repository >
Insubria Thesis Repository >
01 - Tesi di dottorato >

Please use this identifier to cite or link to this item: http://hdl.handle.net/10277/879

Authors: Cattoni, Maria Angela
Internal Tutor: IMPERATORI, ANDREA SELENITO
Title: Evaluation of a new ultrasonic device for surgical dissection in lung lobectomy and lymphadenectomy for lung cancer
Abstract: Objective To assess and compare surgical electric hook vs Harmonic ACE Plus® impact on short-term postoperative outcomes after video-assisted thoracoscopic (VATS) lung lobectomy and lymphadenectomy for non-small cell lung cancer (NSCLC). Materials and methods We prospectively collected data of 120 consecutive patients [60% male; median age: 71 (62-76 IQR:) years] undergoing lung lobectomy and lymphadenectomy by VATS for NSCLC in our Center from October 1st 2016 to July 31th 2019. Patients were divided in two groups based on the device used for tissue dissection: the electric hook (Group A) in 68 cases and the Harmonic ACE Plus® (Group B) in 52. Multivariable analysis by binary logistic regression was performed in order to test the energy device as possible risk factor for pleural effusion volume at 48 hours after surgery and for postoperative chest tube duration. Results No intraoperative complications due to energy device were recorded in both groups. Chylothorax incidence was higher in Group A with no statistically significant difference between the two groups (3% vs 0%; p-value=0.50). Pleural effusion volume during the first 48 postoperative hours was significantly higher in Group B: 253 ml (IQR: 149-405) vs 408 (IQR: 294-508) ml (p-value<0.01). However, chest tube duration was similar in the two groups: 4 (IQR: 3-8) vs 5 (IQR: 4-8) days (p-value=0.39). At multivariable analysis energy device was not independently associated with pleural effusion volume at 48 hours after surgery and with postoperative chest tube duration. Conclusions Electric hook or Harmonic ACE Plus® use during VATS lobectomy for NSCLC is safe and leads to similar postoperative short-term outcomes.
Keywords: Energy device, VATS lobectomy, non-small cell lung cancer
Subject MIUR : MED/21 CHIRURGIA TORACICA
Issue Date: 2019
Language: eng
Doctoral course: Biotecnologie, bioscienze e tecnologie chirurgiche
Academic cycle: 32
Publisher: Università degli Studi dell'Insubria
Citation: Cattoni, M.A.Evaluation of a new ultrasonic device for surgical dissection in lung lobectomy and lymphadenectomy for lung cancer (Doctoral Thesis, Università degli Studi dell'Insubria, 2019).

Files in This Item:

File Description SizeFormatVisibility
PhD_Thesis_CattoniMariaAngela_completa.pdftesto completo tesi366,06 kBAdobe PDFView/Open

This item is licensed under a Creative Commons License
Creative Commons


Items in InsubriaSPACE are protected by copyright, with all rights reserved, unless otherwise indicated.


Share this record
Del.icio.us

Citeulike

Connotea

Facebook

Stumble it!

reddit


 

  ICT Support, development & maintenance are provided by the AePIC team @ CILEA. Powered on DSpace Software.  Feedback